Cee config system messages, Chapter 13, Ccfg-1001 – Dell POWEREDGE M1000E User Manual

Page 165: Ccfg-1002, Ccfg-1003, Ccfg-1004, Chapter

Advertising
background image

Fabric OS Message Reference

89

53-1001767-01

Chapter

13

CEE CONFIG System Messages

CCFG-1001

Message

<timestamp>, [CCFG-1001], <sequence-number>,, ERROR, <system-name>, Failed to

initialize <module>, rc = <error>.

Probable Cause

Indicates that initialization of a module within the Converged Enhanced Ethernet (CEE)
configuration management daemon has failed.

Recommended

Action

Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual
for more information on this command.

Severity

ERROR

CCFG-1002

Message

<timestamp>, [CCFG-1002], <sequence-number>,, INFO, <system-name>, Started

loading CEE system configuration.

Probable Cause

Indicates that the Converged Enhanced Ethernet (CEE) system configuration has started loading.

Recommended

Action

No action is required.

Severity

INFO

CCFG-1003

Message

<timestamp>, [CCFG-1003], <sequence-number>,, INFO, <system-name>, System is

ready to accept CEE user commands.

Probable Cause

Indicates that the Converged Enhanced Ethernet (CEE) shell is ready to accept configuration
commands from the user.

Recommended

Action

No action is required.

Severity

INFO

CCFG-1004

Message

<timestamp>, [CCFG-1004], <sequence-number>,, ERROR, <system-name>, Configuration

replay failed due to missing system startup configuration.

Advertising