Ssm system messages, Chapter 96, Ssmd-1001 – Dell POWEREDGE M1000E User Manual

Page 673: Ssmd-1002, Ssmd-1003, Ssmd-1004, Chapter

Advertising
background image

Fabric OS Message Reference

597

53-1001767-01

Chapter

96

SSM System Messages

SSMD-1001

Message

<timestamp>, [SSMD-1001], <sequence-number>,, ERROR, <system-name>,Failed to

allocate memory: <function name>.

Probable Cause

Indicates that the specified function has failed to allocate memory.

Recommended

Action

Check the memory usage on the switch using the memShow command.

Restart or power cycle the switch.

Severity

ERROR

SSMD-1002

Message

<timestamp>, [SSMD-1002], <sequence-number>,, ERROR, <system-name>,Failed to

initialize <module> rc = <error>.

Probable Cause

Indicates that an initialization of a module within the SSM has failed.

Recommended

Action

Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual
for more information on this command.

Severity

ERROR

SSMD-1003

Message

<timestamp>, [SSMD-1003], <sequence-number>,, ERROR, <system-name>,Failed to lock

semaphore mutex: <function name>.

Probable Cause

Indicates that the specified function has failed to lock the mutex (semaphore).

Recommended

Action

Restart or power cycle the switch.

Severity

ERROR

SSMD-1004

Message

<timestamp>, [SSMD-1004], <sequence-number>,, ERROR, <system-name>,Failed to

unlock semaphore mutex: <function name>.

Advertising