Fcpd system messages, Chapter 32, Fcpd-1001 – Dell POWEREDGE M1000E User Manual

Page 287: Fcpd-1002, Fcpd-1003, Chapter

Advertising
background image

Fabric OS Message Reference

211

53-1001767-01

Chapter

32

FCPD System Messages

FCPD-1001

Message

<timestamp>, [FCPD-1001], <sequence-number>,, WARNING, <system-name>, Probing

failed on <error string>

.

Probable Cause

Indicates that a Fibre Channel Protocol (FCP) switch probed devices on a loop port, and probing
failed on the L_Port, AL_PA address, or the F_Port. For the AL_PA, the valid range is 00 through FF.
The error string can be either of the following:

L_Port port_number ALPA alpa_number

F_Port port_number

Recommended

Action

This can happen when the firmware on the device controller on the specified port has a defect.
Check with the device vendor for a firmware upgrade containing a defect fix.

Severity

WARNING

FCPD-1002

Message

<timestamp>, [FCPD-1002], <sequence-number>,, WARNING, <system-name>, port <port

number>, bad R_CTL for fcp probing: 0x<R_CTL value>

Probable Cause

Indicates that the response frame received on the specified port for an inquiry request contains an
invalid value in the routing control field.

Recommended

Action

This can happen only if the firmware on the device controller on the specified port has a defect.
Check with the device vendor for a firmware upgrade containing a defect fix.

Severity

WARNING

FCPD-1003

Message

<timestamp>, [FCPD-1003], <sequence-number>,, INFO, <system-name>, Probing failed

on

<error string>

which is possibly a private device which is not supported in

this port type

Probable Cause

Indicates that private devices will not respond to the switch port login (PLOGI) during probing.

Recommended

Action

The Brocade DCX, 4100, 4900, 5000, 7500, and AP 7600 do not support private loop devices.
Refer to the switch vendor for a list of other port types that support private devices for inclusion into
the fabric.

Severity

INFO