HLO-1001

Message

<timestamp>, [HLO-1001], <sequence-number>, FFDC, ERROR, <system-name>,

Incompatible Inactivity timeout <dead timeout> from port <port number>, correct

value <value>.

Probable Cause

Indicates that the HLO message was incompatible with the value specified in the FSPF protocol.
The Brocade switch will not accept FSPF frames from the remote switch.

In the Fabric OS, the HLO dead timeout value is not configurable, so this error can only occur when
the Brocade switch is connected to a switch from another manufacturer.

Recommended

Action

The dead timeout value of the remote switch must be compatible with the value specified in the
FSPF protocol. Refer to the documentation for the other manufacturer's switch to change this
value.

Severity

ERROR

HLO-1002

Message

<timestamp>, [HLO-1002], <sequence-number>, FFDC, ERROR, <system-name>,

Incompatible Hello timeout <HLO timeout> from port <port number>, correct value

<correct value>.

Probable Cause

Indicates that the HLO message was incompatible with the value specified in the FSPF protocol.
The Brocade switch will not accept FSPF frames from the remote switch.

In the Fabric OS, the HLO timeout value is not configurable, so this error can only occur when the
Brocade switch is connected to a switch from another manufacturer.

Recommended

Action

The HLO timeout value of the remote switch must be compatible with the value specified in the
FSPF protocol. Refer to the documentation for the other manufacturer's switch to change this
value.

Severity

ERROR

HLO-1003

Message

<timestamp>, [HLO-1003], <sequence-number>, FFDC, ERROR, <system-name>, Invalid

Hello received from port <port number>, Domain = <domain ID>, Remote Port =<remote

port ID>.

Probable Cause

Indicates that the HLO message received was invalid and the frame was dropped. The Brocade
switch will not accept FSPF frames from the remote switch.