SYSM-1001

Message

<timestamp>, [SYSM-1001], <sequence-number>, FFDC, CRITICAL, <system-name>, No

memory.

Probable Cause

Indicates the switch has run out of system memory.

Recommended

Action

Run the memShow command to view the switch memory usage.

Restart or power cycle the switch.

Run the supportFtp command to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.

Severity

CRITICAL

SYSM-1002

Message

<timestamp>, [SYSM-1002], <sequence-number>,, INFO, <system-name>, <number>,

Switch: <Switch number>

Probable Cause

Indicates a user has executed either the switchShutdown or switchReboot command. All services
are brought down for a logical switch.

Recommended

Action

No action is required if the switchShutdown or switchReboot command was executed intentionally.
If the switchShutdown command was run, you must run the switchStart command to restart traffic
on the logical switch.

Severity

INFO

SYSM-1003

Message

<timestamp>, [SYSM-1003], <sequence-number>,, INFO, <system-name>, <number>,

Switch: <start reason>

Probable Cause

Indicates the user executed the switchStart or switchReboot command. This indicates that all
services are brought back up after a temporary shutdown of that logical switch.

Recommended

Action

No action is required if the switchStart command was executed intentionally. Because reinitializing
a switch is a disruptive operation and can stop I/O traffic, you might have to stop and restart the
traffic during this process.

Severity

INFO