Rkd system messages, Chapter 84, Rkd-1001 – Dell POWEREDGE M1000E User Manual

Page 567: Rkd-1002, Rkd-1003, Chapter

Advertising
background image

Fabric OS Message Reference

491

53-1001767-01

Chapter

84

RKD System Messages

RKD-1001

Message

<timestamp>, [RKD-1001], <sequence-number>,, INFO, <system-name>, <Re-key type

(First time encryption/Rekey/Write Metadata)> operation <Re-key action

(started/completed/cancelled)>.\nTarget: <Target physial WWN>, Initiator:

<Initiator physical WWN>, LUN ID: <LUN ID>.\n SessionId:<Session ID>/<Session MN>

Probable Cause

Indicates that a First time encryption/re-key/Write Metadata was started/completed/cancelled.

Recommended

Action

No action is required.

Severity

INFO

RKD-1002

Message

<timestamp>, [RKD-1002], <sequence-number>,, ERROR, <system-name>, Could not

start <Re-key type (First time encryption/Rekey/Write Metadata)>

operation.\n<I/T/L String>.\n No response from cluster member WWN: <EE WWN> Slot:

<EE Slot Number>.

Probable Cause

Indicates that a First time encryption/re-key/Write Metadata was not started.

Recommended

Action

Correct the Cluster Ethernet link error and retry.

Severity

ERROR

RKD-1003

Message

<timestamp>, [RKD-1003], <sequence-number>,, CRITICAL, <system-name>, <Re-key

type (First time encryption/Rekey/Write Metadata)> encountered a FATAL SCSI error

and will be suspended.\n<I/T/L String>.\nCommand: <Read/Write>\nLBA: <LBA>\nNum

Blocks: <Num of Blocks>\nError: <Error String>\nSK/ASC: <SCSI Sense Key>/<SCSI

ASC>.

Probable Cause

Indicates that a First time encryption/re-key/Write Metadata encountered a fatal SCSI error and
was suspended.

Recommended

Action

Correct the error and resume.

Severity

CRITICAL