Brick, Fuses, 1025fa series, fast acting – Cooper Bussmann BRICK 6125TD User Manual

Page 11

Advertising
background image

Description

• Surface Mount
• Environmentally rugged, satisfies the EIA/IS-722

Standard

• Solder Immersion Compatible
• Targeted for Consumer Electronics

Note: 30vde constant current source required for 200%

overload tests on 250ma-1a.

Agency Information
• UL Recognition Guide & File numbers:

JDYX2 & E19180 (250mA - 15A)

• CSA Component Acceptance:

File # 053787 C000, Class # 1422 30

Environmental Data
• Life Test: MIL-STD-202, Method 108A, Test Condition D
• Load Humidity: MIL-STD-202, Method 103B
• Moisture Resistance: MIL-STD-202, Method 106E
• Terminal Strength: MIL-STD-202, Method 211A
• Thermal Shock: MIL-STD-202, Method 107D, air-to-air
• Case Resistance: EIA/IS-722
• Resistance to Dissolution of Metallization:

ANSI J-STD-002, Test D

• Mechanical Shock: MIL-STD-202, Method 213B with

exceptions per EIA/IS-722 Standard

• High Frequency Vibration: MIL-STD-202, Method 204D,

Test Condition D

• Resistance to Solvents: MIL-STD-202, Method 215A

Soldering Method

• Wave Solder: 260°C, 10 sec max.
• Infrared Reflow: 260°C, 30 sec max.

Ordering

• Specify product code and packaging code

3.30

(0.130)

4.38

(0.172)

6.79

(0.267)

Land Pattern

Dimensions

mm

(inches)

Drawing Not to Scale

Brick

Fuses

1025FA Series, Fast Acting

ELECTRICAL CHARACTERISTICS

% of Amp Rating

Opening Time

100%

4 Hours Minimum

200% (250mA-5A)

5 Seconds Maximum

250% (250mA-5A fuse)

1 Second Maximum

200% (7A-15A fuse)

20 Seconds Maximum

250% (7A-15A fuse)

4 Seconds Maximum

SPECIFICATIONS

Voltage

Interrupting

DC Cold

Typical

Typical

Marking

Product Code

Rating

Rating*

Resistance** (ohms)

Melting

Voltage

Code‡‡

AC DC

250VAC 125VDC 60VDC

Typical

I

2

t†

Drop‡

1025FA250mA

250V 125V

50A

50A

-

5.0000

0.1212

2019 mV

AD

1025FA500mA

250V 125V

50A

50A

-

1.2000

0.0415

1500 mV

AF

1025FA750mA

250V 125V

50A

50A

-

0.6000

0.143

880 mV

AG

1025FA1A

250V 125V

50A

50A

-

0.3000

1.750

560 mV

AH

1025FA1.5A

250V 125V

50A

50A

-

0.1040

1.460

260 mV

AK

1025FA2A

250V 125V

50A

50A

-

0.0800

6.086

258 mV

AN

1025FA2.5A

250V 125V

50A

50A

-

0.0510

8.48

232 mV

AO

1025FA3A

250V 125V

50A

50A

-

0.0390

18.15

205 mV

AP

1025FA3.5A

250V 125V

50A

50A

-

0.0300

17.83

185 mV

AR

1025FA4A

250V 125V

50A

50A

-

0.0270

23.32

190 mV

AS

1025FA5A

250V 125V

50A

50A

-

0.0200

38.74

180 mV

AT

1025FA7A

250V 60V

50A

50A

-

0.0116

138

150 mV

AU

1025FA10A

250V 60V

50A

50A

-

0.0076

457

146 mV

AW

1025FA12A

250V 60V

50A

-

50A

0.0550

498

120 mV

AX

1025FA15A

250V 60V

50A

-

50A

0.0041

1451

110 mV

AY

* AC Interrupting Rating (Measured at designated voltage, 100% power factor random closing); DC Interrupting Rating (Measured at designated voltage, time constant of

less than 50 microseconds, battery source)

** DC Cold Resistance (Measured at

10% of rated current)

† Typical Melting I

2

t (Measured with a battery bank at rated DC voltage, 10x-rated current, but not exceeding the interrupting rating. Time constant of calibrated circuit less

than 50 microseconds). Test current not to exceed interrupting rating of 50A.

‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
‡‡ Marking Code - 3

rd

(U = USA, T = Taiwan and S = China)

• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at

elevated ambient temperatures.