Brick, Fuses, 1025t series time lag, low breaking capacity – Cooper Bussmann BRICK 6125TD User Manual

Page 5: Specifications, Land pattern dimensions

Advertising
background image

Description

• Designed to IEC 127-4
• Surface Mount fuse, time lag
• Solder Immersion Compatible
• Overcurrent protection of systems up to 250VAC

Approvals

• Designed to IEC 127, Sheet 4 (approval pending)

Environmental Data

• Termination Strength: IEC 127-4 Clause 8.3.2
• Soldered Joints: IEC 127-1 Clause 8.5
• Solderability: IEC 127-4 Clause 8.6.2 subjected to Test

Td of IEC-68-2-58 with the following conditions; Aging:
none. Immersion conditions: exceeds IEC 127-4.
Depth of immersion: entire metal surface. Flux type:
non-activated. Solder type: 60% tin and 40% lead
according to IEC 68-2-20, Appendix B.

• Resistance to Soldering Heat: IEC 127-4 Clause 8.7

subjected to Test Td of IEC 68-2-58 with the following
conditions; Aging: none. Immersion conditions: 260°C
± 5°C, 10 seconds ± 1 sec. Depth of immersion:
10mm. Flux type: activated. Solder type: 60% tin and
40% lead

• Insulation Resistance: IEC 127-4, Clause 9.3.3

(resistance

0.1Mohms)

Ordering

• Specify product code and packaging code

Soldering Method

• Wave Immersion: 260°C, 10 sec max.
• Infrared: 260°C, 30 sec max.

3.07

±

0.15

(0.121

±

0.006)

2.77

±

0.15

3.07

±

0.15

(0.109

±

0.006)

(0.121

±

0.006)

2.77

±

0.15

(0.109

±

0.006)

3.30

(0.130)

4.38

(0.172)

6.79

(0.267)

1.4

±

0.25

1.4

±

0.25

(0.055

±

0.010)

(0.055

±

0.010)

2.77

±

0.15

(0.109

±

0.006)

3.07

±

0.15

(0.121

±

0.006)

10.29

±

0.20

(0.405

±

0.008)

1.4

±

0.25

1.4

±

0.25

(0.055

±

0.010)

(0.055

±

0.010)

2.77

±

0.15

(0.109

±

0.006)

3.07

±

0.15

(0.121

±

0.006)

10.29

±

0.20

(0.405

±

0.008)

Land Pattern

Dimensions

mm

(inches)

Drawing Not to Scale

Top View

Side View

End View

Brick

Fuses

1025T Series

Time Lag, Low Breaking Capacity

ELECTRICAL CHARACTERISTICS

% of Amp Rating

Opening Time

125%

1 Hours Minimum

200%

2 Minutes Maximum

200%

1 Second Minimum

1000%

0.01 -- 0.1 Seconds

SPECIFICATIONS

Voltage

Interrupting

DC Cold

Typical

Typical

Max.

Marking

Product Code

Rating

Rating*

Resistance** (ohms)

Melting

Voltage

Voltage

Code

AC DC

250VAC 125VDC

min.

typ.

max.

I

2

t†

Drop‡

Drop‡

1025T250mA

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

800

Dt

1025T500mA

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

600

Ft

1025T800mA

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

400

KKt

1025T1A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

300

Ht

1025T1.6A

250V 125V

100A 50A

0.064 0.074 0.083

12.26

155 mV

300

MMt

1025T2A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

300

Nt

1025T2.5A

250V 125V

100A 50A

0.045 0.048 0.051

32.91

TBD

300

Ot

1025T3.15A

250V 125V

100A 50A

0.030 0.034 0.038

54.98

184 mV

300

Qt

1025T4A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

300

St

1025T5A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

300

Tt

1025T6.3A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

300

OOt

* AC Interrupting Rating (Measured at designated voltage, greater than 95% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of

the calibrated circuit is less than 1 millisecond, battery source)

** DC Cold Resistance (Measured at

10% of rated current)

† Typical Melting I

2

t (Measured with a battery bank at rated DC voltage, 10x-rated current, not to exceed IR, time constant of calibrated circuit less than 50 microseconds)

‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at

elevated ambient temperatures.