Brick, Fuses, 1025f series fast acting, low breaking capacity – Cooper Bussmann BRICK 6125TD User Manual

Page 7: Specifications, Land pattern dimensions

Advertising
background image

Description

• Surface mount fuse, fast acting
• Designed to IEC 127-4
• Surface Mount
• Solder Immersion Compatible
• Overcurrent protection of systems up to 250 VAC

Approvals

• Designed to IEC 127, Sheet 4 (approval pending)

Environmental Data

• Termination Strength: IEC 127-4 Clause 8.3.2
• Soldered Joints: IEC 127-1 Clause 8.5
• Solderability: IEC 127-4 Clause 8.6.2
• Resistance to Soldering Heat: IEC 127-4 Clause 8.7
• Insulation Resistance: IEC 127-4 Clause 9.3.3

Soldering Method

• Wave Immersion: 260°C, 10 sec max.
• Infrared: 260°C, 30 sec max.

Ordering

• Specify product code and packaging code

2.77

±

0.15

(0.109

±

0 .006)

2.77

±

0.15

(0.109

±

0 .006)

3.07

±

0.15

(0.121

±

0.006)

3.07

±

0.15

(0.121

±

0.006)

4.38

(0.172)

3.30

(0.130)

6.79

(0.267)

2.77

±

0.15

(0.109

±

0 .006)

10.29

±

0.20

(0.405

±

0 .008)

1.4

±

0.25

(0.055

±

0.010)

1.4

±

0.25

(0.055

±

0.010)

3.07

±

0.15

(0.121

±

0 .006)

2.77

±

0.15

(0.109

±

0.006)

10.29

±

0.20

(0.405

±

0.008)

1.4

±

0.25

(0.055

±

0.010)

1.4

±

0.25

(0.055

±

0.010)

3.07

±

0.15

(0.121

±

0.006)

Land Pattern

Dimensions

mm

(inches)

Drawing Not to Scale

Top View

Side View

End View

Brick

Fuses

1025F Series

Fast Acting, Low Breaking Capacity

ELECTRICAL CHARACTERISTICS

% of Amp Rating

Opening Time

125%

1 Hour Minimum

200%

2 Minutes Maximum

1000%

0.001 - 0.01 Seconds

SPECIFICATIONS

Voltage

Interrupting

DC Cold

Typical

Typical

Marking

Product Code

Rating

Rating*

Resistance** (ohms)

Melting

Voltage

Code

AC DC

250VAC 125VDC

min.

typ.

max.

I

2

t†

Drop‡

1025F250mA

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

D f

1025F500mA

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

F f

1025F800mA

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

KK f

1025F1A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

H f

1025F1.6A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

MM f

1025F2A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

N f

1025F2.5A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

O f

1025F3.15A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

Q f

1025F4A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

S f

1025F5A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

T f

1025F6.3A

250V 125V

100A 50A

TBD TBD TBD

TBD

TBD

OO f

* AC Interrupting Rating (Measured at designated voltage, greater than 95% power factor); DC Interrupting Rating (Measured at designated voltage,

time constant of the calibrated circuit is less than 1 millisecond, battery source)

** DC Cold Resistance (Measured at

10% of rated current)

† Typical Melting I

2

t (Measured with a battery bank at 10x-rated current, not to exceed IR,

time constant of calibrated circuit less than 50 microseconds)

‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with

further derating required at elevated ambient temperatures.