Brick, Fuses, 1025td series, time delay – Cooper Bussmann BRICK 6125TD User Manual

Page 13: Specifications

Advertising
background image

Description

• Surface Mount
• Environmentally rugged, satisfies the EIA/IS-722

Standard

• Solder Immersion Compatible
• Targeted for Consumer Electronics

* If fuse does not open @ 200% in 60 seconds, raise current to 250%

and the fuse must open in 10 seconds maximum.

Agency Information

• UL Recognition Guide & File numbers:

JDYX2 & E19180 (250mA - 5A)

• CSA Component Acceptance:

File # 053787 C000, Class # 1422 30

Environmental Data

• Life Test: MIL-STD-202, Method 108A, Test Condition D
• Load Humidity: MIL-STD-202, Method 103B
• Moisture Resistance: MIL-STD-202, Method 106E
• Terminal Strength: MIL-STD-202, Method 211A
• Thermal Shock: MIL-STD-202, Method 107D, air-to-air
• Case Resistance: EIA/IS-722
• Resistance to Dissolution of Metallization:

ANSI J-STD-002, Test D

• Mechanical Shock: MIL-STD-202, Method 213B with

exceptions per EIA/IS-722 Standard

• High Frequency Vibration: MIL-STD-202, Method 204D,

Test Condition D

• Resistance to Solvents: MIL-STD-202, Method 215A

Ordering

• Specify product code and packaging code

Soldering Method

• Wave Immersion: 260°C, 10 sec max.
• Infrared: 260°C, 30 sec max.

3.30

(0.130)

4.38

(0.172)

6.79

(0.267)

Land Pattern

Dimensions

mm

(inches)

Drawing Not to Scale

Brick

Fuses

1025TD Series, Time Delay

ELECTRICAL CHARACTERISTICS

% of Amp Rating

Opening Time

100%

4 Hours Minimum

200%

1 Second Minimum

200%

60 Seconds Maximum

250% *

10 Seconds Maximum

SPECIFICATIONS

Voltage

Interrupting

DC Cold

Typical

Typical

Marking

Product Code

Rating

Rating*

Resistance** (ohms)

Melting

Voltage

Code‡‡

AC DC

250VAC 125VDC

Typical

I

2

t†

Drop‡

1025TD250mA

250V 125V

50A 50A

4.200

0.128

1900 mV

DD

1025TD500mA

250V 125V

50A 50A

0.5500

1.47

455 mV

DF

1025TD750mA

250V 125V

50A 50A

0.317

0.93

400 mV

DG

1025TD1A

250V 125V

50A 50A

0.2030

9.91

387 mV

DH

1025TD1.5A

250V 125V

50A 50A

0.1025

11.79

310 mV

DK

1025TD2A

250V 125V

50A 50A

0.0680

17.27

250 mV

DN

1025TD2.5A

250V 125V

50A 50A

0.0420

16.51

201 mV

DO

1025TD3A

250V 125V

50A 50A

0.0330

42.74

184 mV

DP

1025TD3.5A

250V 125V

50A 50A

0.0270

43.33

180 mV

DR

1025TD4A

250V 125V

50A 50A

0.0220

66.96

152 mV

DS

1025TD5A

250V 125V

50A 50A

0.0160

88.38

145 mV

DT

* AC Interrupting Rating (Measured at designated voltage, 100% power factor random closing); DC Interrupting Rating (Measured at designated voltage, time

constant of the calibrated circuit is less than 50 microseconds, battery source)

** DC Cold Resistance (Measured at

10% of rated current)

† Typical Melting I

2

t (Measured with a battery bank at rated DC voltage, 10x-rated current, time constant of calibrated circuit less than 50 microseconds)

‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
‡‡ Marking Code - 3

rd

(U = USA, T = Taiwan and S = China)

• Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at

elevated ambient temperatures.