Brick, Fuses, 6125fa series, fast acting – Cooper Bussmann BRICK 6125TD User Manual

Page 9: Specifications

Advertising
background image

Description

• Surface Mount
• Environmentally rugged, complies with the EIA-IS-722

Standard

• Solder Immersion Compatible
• Targeted for Consumer Electronics
• Overcurrent protection of systems up to 125VAC/DC
• Wire-in-air design

Agency Information

• UL Listed Guide and File Numbers (250mA-12A):

JDYX & E195337

• UL Recognized Guide and File Numbers (15A):

JDYX2 & E195337

• CSA Component Acceptance: 053787 C 000 &

Class No: 1422 30

Environmental Data

• Shock: MIL-STD-202, Method 213, Test Condition 1

(100 G’s peak for 6 milliseconds)

• Vibration: MIL-STD-202, Method 201 (10-55 Hz, 0.06

inch, total excursion)

• Salt Spray: MIL-STD-202, Method 101, Test Condition

B (48 hrs)

• Insulation Resistance: MIL-STD-202, Method 302, Test

Condition A (After Opening) 10,000 ohms minimum

• Resistance to Solder Heat: MIL-STD-202, Method 210,

Test Condition F (20 sec, at 260° C)

• Thermal Shock: MIL-STD-202, Method 107, Test

Condition B (-65° C to +125° C)

Ordering

• Specify product code and packaging code

Soldering Method

• Wave Solder: 260°C, 10 sec max.

(MIL-STD-202, Method 210)

• Infrared Reflow: 260°C, 30 sec max.

Brick

Fuses

6125FA Series, Fast Acting

2.59+ .250

(0.102+.010)

2.59+ .250

(0.102+.010)

2.6

3.0

(0.102)

(0.118)

4.0

(0.157)

8.6

(0.339)

*

AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than 50
microseconds, battery source)

** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I

2

t (Measured with a battery bank at rated DC voltage, 10x-rated current, time constant of calibrated circuit less than 50 microseconds)

‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated
ambient temperatures.

1.35+ .25

1.35+.25

(0.053+ .010)

(0.053+.010)

2.59+ .25

(0.102+.010)

6.10+.25

(0.240+.010)

1.35+.25

1.35 +.25

(0.053+.010)

(0.053+.010)

2.59+.25

(0.102+.010)

6.10+.25

(0.240+.010)

Land Pattern

Dimensions

mm

(inches)

Drawing Not to Scale

Top View

Side View

End View

ELECTRICAL CHARACTERISTICS

% of Amp Rating

Opening Time

100%

4 Hours Minimum

200%

5 Seconds Maximum

SPECIFICATIONS

Product

Voltage

Interrupting

Resistance

Typical

Typical

Code

Rating

Rating*

(ohms)**

Melt

Voltage

AC

DC

DC

125V AC 125V DC 86V DC

Typ.

I

2

t†

Drop (V)‡

6125FA250mA

125V

125V

86V

50A

300A

10,000A

0.65

0.01

0.30

6125FA375mA

125V

125V

86V

50A

300A

10,000A

0.36

0.03

0.25

6125FA500mA

125V

125V

86V

50A

300A

10,000A

0.24

0.06

0.22

6125FA750mA

125V

125V

86V

50A

300A

10,000A

0.15

0.07

0.17

6125FA1A

125V

125V

86V

50A

300A

10,000A

0.11

0.14

0.17

6125FA1.25A

125V

125V

86V

50A

300A

10,000A

0.09

0.24

0.16

6125FA1.5A

125V

125V

86V

50A

300A

10,000A

0.07

0.41

0.15

6125FA2A

125V

125V

86V

50A

300A

10,000A

0.05

0.80

0.15

6125FA2.5A

125V

125V

86V

50A

300A

10,000A

0.038

1.4

0.14

6125FA3A

125V

125V

86V

50A

300A

10,000A

0.028

2.4

0.13

6125FA3.5A

125V

125V

86V

50A

300A

10,000A

0.025

3.3

0.13

6125FA4A

125V

125V

86V

50A

300A

10,000A

0.022

4.4

0.13

6125FA5A

125V

125V

86V

50A

300A

10,000A

0.016

7.8

0.12

6125FA6.3A

125V

125V

86V

50A

300A

10,000A

0.012

14.0

0.12

6125FA7A

125V

125V

86V

50A

300A

10,000A

0.011

19.0

0.114

6125FA10A

125V

N/A

86V

50A

N/A

10,000A

0.007

44

0.107

6125FA12A

125V

N/A

86V

50A

N/A

10,000A

0.006

69

0.103

6125FA15A

N/A

N/A

86V

N/A

N/A

10,000A

0.004

124

0.098

Advertising