Error logs and diagnostics page, Viewing error or history logs, Running diagnostics tests – Dell PowerVault 124T User Manual

Page 26

Advertising
background image

NOTE: It is recommended that all firmware updated be performed with image files located on

the local system hard drive as opposed to a removable media device or network share.

3. Click Upload.

4. Click OK in response to the confirmation box. The autoloader automatically uploads the new code

and processes it to the system.

NOTE: A Microsoft issue may keep a user from updating drive or loader firmware over the RMU

interface. This can occur under Windows Server® 2003 with Service Pack 1 (SP1), or if a user

has installed Microsoft Security Update MS05-019. This problem displays as a 6F Communication
Error message on the front panel with the warning light set. The RMU will continue to report

the autoloader status as Initialization.

For information and a workaround to this problem, go to

Microsoft Technical Support Article

898060

. If this problem occurs, the autoloader should be restarted to avoid further

communication errors.

5. Power cycle the loader, then the server firmware update is complete.

NOTE: After firmware update is complete, the unit will report new revision levels to the host on

startup. You may have to reconfigure you host backup software to recognize the updated unit.

Error Logs and Diagnostics Page

From the Error Log and Diagnostics page, you can run various tests on the autoloader. You can also view

error and history logs, test progress, identify the physical unit in a rack, or reset the system.

Viewing Error or History Logs:

1. From any page, click the Diagnostics heading. The Diagnostics screen will be displayed.

2. Under View Error and History Logs, click View Logs. You can also save the logs to a file by clicking

Save Logs. If you save the logs to a file, you must select a destination folder within 60 seconds.

NOTE: Saved logs taken at point of failure are valuable for assessing problems. Service

personnel may request these logs.

Running Diagnostics Tests

A minimum of two cartridges are required to run the diagnostic tests. The diagnostic tests available on the

autoloader include:

Loader - Picker Test

Loader - Magazine Test

Loader - Inventory Test

Random Moves

1. From any page, click the Error Log and Diagnostics heading. The Error Log and Diagnostics screen

will be displayed.

2. In the Diagnostics section, select the diagnostic test that you want to run from the Test drop-down

menu.