MCBF

100,000 cartridge load/unload cycles

Interface

Serial Attached SCSI (SAS)

Initialize element

status

90 seconds (typical)

Typical cycle time < 40 seconds. One cycle consists of moving a cartridge from the tape drive to a

magazine slot, selecting another magazine slot, and then moving the cartridge back to

the tape drive. It does not include the time that the tape drive takes to unload or

load/calibrate.

Average load

time (after

placing cartridge

in drive)

LTO Ultrium 6 = 12 seconds (to BOT for previously written tape)

LTO Ultrium 6 = 12 seconds (to BOT with initialized tape)

Average unload

time (from BOT)

LTO Ultrium 6 = 17 seconds (from BOT)

Autoloader Environmental Specifications

Characteristic Specification

Temperature Range (Dry Bulb)

Operating

+10º to +45ºC

Nonoperating –40º to +65ºC

Temperature Variation

Operating

10ºC per hour

Nonoperating 11ºC per hour

Humidity

Operating

10% to 80% non-condensing

Nonoperating 10% to 90% non-condensing

Gradient

30% per hour without condensation