24

Software Error

25

Hardware Error

Message Error Types

26

Message Sender (Task )

ID Error

Verify the host backup application and device driver are at the

latest supported revision at

support.dell.com

.

Check host adapter and SAS cables.

Power cycle the autoloader and retry the operation.

If all previous steps fail, see

Contacting Dell

.

27

Message Type Bad

28

Message Parameter Bad

Stack/Global Data Corruption Error Types

29

Invalid Element

Verify the host backup application and device driver are at the

latest supported revision at

support.dell.com

.

Power cycle the autoloader.

Run the Random Moves test from either the Remote Management

Unit (RMU) or the Operator Control Panel (OCP).

Note: The Random Moves test requires a minimum of two

cartridges present within the autoloader.

If all previous steps fail, see

Contacting Dell

.

2A

Invalid Element Status

2B

Element Table Bad

2C

Global Data Bad

2D

Stack Data Bad

2E

Task Stack Low

2F

Task Stack Overflow

System Shutdown/Disruption Error Types

30

POST Failure

Verify that the magazines/magazine blank are fully seated.

Power cycle the autoloader.

If all previous steps fail, see

Contacting Dell

.

31

Watchdog Timer

Power cycle the autoloader.

Run the Random Moves test from either the Remote Management

Unit (RMU) or the Operator Control Panel (OCP).

Note: The Random Moves test requires a minimum of two

cartridges present within the autoloader.

Check

support.dell.com

for PowerVault 124T firmware updates.

see

Contacting Dell

.

32

Power Event

33

Power Down Failure

34

System Overload

35

System Performance

36

Asynchronous Stop

System Miscellaneous Error Types

37

System Cleaning Error

Cleaning slot in use.

Verify that a valid cleaning cartridge is located in the dedicated

cleaning slot indicated within the Remote Management Unit

Configuration page settings.