Crmu, Clk div & gating – Achronix Speedster22i Clock and Reset Networks User Manual

Page 18

Advertising
background image

18

UG027, May 21, 2014

CRMU

32 to 8

Crossbar

Additional

Control

Logic

32 to 8

Crossbar

Additional

Control

Logic

Clk Div &

Gating

Clk Div &

Gating

6

24

2

6

24

Global Core Clocks
from Clock Hub

Direct Core Clocks
from Clock Mux

2

From data
interconnect in fabric

16

From data
interconnect in fabric

16

8

8

8

8

16

To Fabric

Columns

Global Core Clocks
from Clock Hub

Direct Core Clocks
from Clock Mux

Figure 9: Detailed View of a Clock Region Management Unit (CRMU)

Figure 10 below provides a more in-depth look at the 3 features available in the CRMU.
Clock division logic is controlled by static configuration memory bits. The clock gate relies on
an “Enable” input to the logic, while the glitchless clock switch module uses select/deselect
logic to select between 2 different clock inputs. The divider and gating or switching logic can
also be cascaded as shown. Note that Figure 10 is a conceptual view of the circuitry for one
instance only and these functions exist for all of the clock inputs.

Clk Div &

Gating

Clock Divider

(1, 2, 4, 6 or 8)

Clock Gate

Clock Switch

Enable

Select /

Deselect

Clk_Out

Clk_In

Clk_In2

Figure 10: Internals of the Clock Division, Gating and Switching Circuitry