3 power connection, 4 welding gas connections – Arc Machines 205 WDR User Manual

Page 15

Advertising
background image

M O D E L 2 0 5

O P E R A T O R ’ S M A N U A L

11

11

11

11

3.3

POWER CONNECTION

To avoid severe equipment damage ensure that the Model 205 power supply is

connected to the correct input AC power as listed in Section 2.0 Specifications.

The Model 205 can operate on any single phase voltage from 100V AC to 240V AC.
Provided the input voltage is within this range, the unit will automatically adjust for the input
voltage.

1. The Model 205 is supplied with a 15 foot power cord. A suitable AC line connector

matching the input power must be supplied and installed by the user. Color coding of
the power cord is as follows:

Green/Yellow:

Equipment grounding conductor

White/Gray:

Grounded circuit conductor, Neutral

Black:

Ungrounded circuit conductor, Line

2. Ensure that the circuit breaker

is in the down or OFF position.

3. Connect the AC line connector to the power cord.

Do not connect the Model 205 to the AC power source until all installation

steps are complete

3.4 WELDING GAS CONNECTIONS

The Model 205 is intended for typical GTAW gases ONLY. NEVER CONNECT

OXYGEN OR ACETYLENE TO THE MODEL 205.

1. The Arc Gas hose is supplied with the Model 205. This hose is made of material

selected specifically for automatic welding. HOSES MADE FROM OTHER
MATERIAL ARE NOT RECOMMENDED (especially rubber, nylon, or tygon).

2. This 10 foot (3 meter) hose should be installed from the gas regulator/flow meter

(user supplied) to the ARC GAS INPUT fitting on the Model 205. The hose is
supplied with the fittings required to mate with the Model 205 and most domestic
(USA) inert gas flow meters.