2 initial power on – Arc Machines 205 WDR User Manual

Page 24

Advertising
background image

M O D E L 2 0 5

O P E R A T O R ’ S M A N U A L

20

20

20

20

4.2 INITIAL POWER ON

Before proceeding with POWER ON it is EXTREMELY important to have a basic

understanding of SYSTEM FUNCTIONS. Read Section 4.1 - System Functions before
proceeding.

1. Before connecting or energizing the AC power verify that all input power set up

requirements of Section 3.0 have been complied with.

2. Connect the AC power cable to the AC source and to the 115/230 VAC INPUT

connector

on the Model 205. Move the circuit breaker to the ON position.

3. If the Model 205-CW is installed connect the AC cord to 110 or 220 VAC, single phase

power. Set the ON/OFF switch to the ON position.

Note

The Model 205-CW contains a flow sensor. The green lamp indicates that there is
sufficient flow. If this lamp goes out either the water level is too low or there is a
blockage in the line. Add coolant or clear the blockage before continuing to weld.

4. Boot-up and display the HOME screen takes approximately one minute.

Advertising