Salter Brecknell S122 User Manual

Page 42

Advertising
background image

5.4 F1 - specification settings

5 Configuration Mode

S122

User /

Service Instructions

42

Unit options are:

digit 1 1= kg, 2= lb
digit 2 0= no 2nd unit
1= kg, 2= lb
digit 3 Must be set to 0
digit 4 0= kg display
1= g display
digit 5 0= lb display
1= lb, oz display
digit 6 Not used

Examples:

kg only 100xxx
lb only 200xxx
kg, lb units 120xxx
lb, kg units 210xxx

To change the flashing digit:

To go to the next digit:

ENTER

U00000

200000

lb primary unit

ENTER

200000

secondary unit

2100 0

kg secondary unit

Must be 0

lb primary unit

Repeat until you have entered
the required oiptions.

Example: 210010
21 = dual units lb and kg
digit 4 = kg displayed
digit 5 = lb, oz displayed

kg displayed

not used

lb, oz displayed

1