1 Features

2 Introduction

S122

User /

Service Instructions

9

2

Introduction

2.1

Features

1.

High performance A/D converter.

0.3

µ

v/ sensitivity

Sample speed 16 times / second

Maximum resolution : 15000

Non-linearity 0.01 % FS

-1 mv ~ +5 mv

Used range -1 mv ~ +14 mv

Load cell excitation power 5VDC

±

5% 100mA.

2.

Adjustable noise filter setting for the range of stability
from 01 ~ 15.

3.

Depending on the calibration division:

Standard division (under 10000)
Capacity and weight must be calibrated.

High precision division (over 10000 to 150000
divisions)
Linearity, capacity and weight must be calibrated.

4.

Option with RS232 output .

5.

Three options for the HOLD function.

6.

AC / DC power supply.

7.

LCD display.

8.

Auto-power cut off to ensure performance stability.
Power is cut off automatically if the power is below the
low battery warning.

9.

Built-in backlight.