14

PS1000/2000 User Instructions

3.6 Hold Function

HOLD function can be used to freeze a displayed number. In this mode, the scale can
capture a dynamic number, hold a stable number, or average a unstable number and
then HOLD (freeze) this number temporarily for the user to view or record.

The HOLD function can be used in normal weighing mode, counting mode and percent
weighing mode. After entering HOLD mode, the speed of A/D converter can be
increased to 80Hz (if USER-HOLD-AD.H.SPD is set to YES) from original 10Hz for
some dynamic weighing applications.

It is possible to weigh restless weighing samples such as live animals or moving objects
within the hold function. The indicator provides special mode settings to accommodate
weight movements.

3.6.1 Access the Hold Mode

To enter the HOLD mode, press the [HOLD] key while in the normal weighing mode.