PS1000/2000 User Instructions

31

Command: U<CR> (55h 0dh)

Command: L<CR> (4ch 0dh)

Command: X<CR> (58h 0dh)

Command: all others

Table 6.4 Summary of Command and Response:

Response

Changes units of measure (simulate UNIT key) and return scale status with new units,
The new measure unit should be allowed to use
<LF> U

1

U

2

<CR><LF> H

1

H

2

H

3

<CR><ETX>

Response

If Hold function can be activated, it will enable/disable hold function (simulate HOLD key) and returns scale status.
<LF> H

1

H

2

H

3

<CR><ETX>

Response

Power off the scale, just like press down the ON/OFF key to turn off the scale.

Response

Unrecognized command
<LF>? <CR><ETX>

Command

Response

ASCII

HEX

W<CR>

57 0d

Read scale weight:
<LF>^^^^^^^^U1U2 U3U4U5<CR><LF> H1H2H3 H4<CR><ETX>---over
capacity
?<LF>________U1U2U3U4U5<CR><LF> H1H2H3 H4<CR><ETX>---under
capacity
?<LF>-------- U1U2 U3 U4U5<CR><LF> H1H2H3 H4<CR><ETX>---zero-point
error
?<LF><p>W1W2W3W4W5<dp>W6U1U2U3U4U5<CR><LF>H1H2H3H4<CR
><ETX>---normal data

S<CR>

53 0d

<LF> H1H2H3H4<CR><ETX>; read scale status

Z<CR>

5a 0d

<LF> H1H2H3H4<CR><ETX>; simulate ZERO key

T<CR>

54 0d

<LF> H1H2H3H4<CR><ETX>; simulate TARE key

U<CR>

55 0d

<LF> U1U2 U3 U4U5<CR><LF> H1H2H3H4<CR><ETX>; simulate UNIT key

L<CR>

4c 0d

<LF> H1H2H3H4<CR><ETX>; simulate HOLD key

X<CR>

58 0d

power off the scale, simulate OFF key

others

<LF>? <CR><ETX>

Advertising