background image

18

PS1000/2000 User Instructions

p15

0-3

1

Weight signal not within
power on zero point range

0 = current weight
1 = calibration zero-point
2 = switch-off zero-point
3 = continuously display 0-----

p16

0-8

8

Zero tracking range

Choose the zero tracking range as per the
stability of weighing system accuracy.
0 = 0d, no tracking
1 = +0.25d
2 = +0.5d
3 = +1d
4 = +1.5d
5 = +2d
6 = +3d
7 = +4d
8 = +5d

p17

0-3

2

Data filter intensity

The larger the digit data filter intensity is
stronger and the speed of data updating is
lower.
0 = very weak
1 = weak
2 = middle
3 = strong

p18

0-9

1

Range of weight stability
checking

0 = +0.5d
1 = ±1d
2 = +2d
3 = +3d
4 = +4d
5 = +5d
6 = +6d
7 = +7d
8 = +8d
9 = +9d

p19

0-9

1

Overload limit range

0 = FS+0d
1 = FS+9d
2 = 101%FS
3 = 102%FS
4 = 105%FS
5 = 110%FS
6 = 120%FS
7 = 150%FS
8 = 200%FS
9 = no limitation