2 specifications, 1 scale platform, 1 capacity – Salter Brecknell PS2000 User Manual
Page 8: 2 dimension, 3 options, 2 scale indicator, 1 power supply, Chapter 2 specifications, Scale platform, Capacity dimension options
6
PS1000/2000 User Instructions
2 Specifications
2.1 Scale Platform
2.1.1 Capacity
l
PS1000: 500 kg x 0.2 kg / 1,000 lb x 0.5 lb
l
PS2000: 1000 kg x 0.5 kg / 2,000 lb x 1.0 lb
2.1.2 Dimension
l
PS1000: 55.75” L x 20.25” W x 2.5” H
m
1416 mm (L) x 514 mm (W) x 64 mm (H)
l
PS2000: 59” L x 30” W x 2.5” H
m
1498 mm (L) x 762 mm (W) x 64 mm (H)
2.1.3 Options
l
Table top stand
l
Floor stand
2.2 Scale Indicator
l
Input signal range: 0mV - +30mV
l
Sensitivity: >0.2µV/grad
l
Internal Resolution: Approximately 520,000 counts
l
Display Resolution: can be selected between 500-100,000
l
System Linearity: within 0.01% of Full Scale
l
Calibration Method: Software calibration with long-term storage in EEPROM
2.2.1 Power Supply
l
Alkaline batteries: 4 AAA size cells (20 hour battery life)
l
AC adapter: 6VDC, 500mA with central negative
l
Work current: .25mA
m
(when voltage in 5Vdc-8Vdc and not include loadcell consumption)