4 commands and response, Commands and response – Salter Brecknell PS2000 User Manual

Page 32

Advertising
background image

30

PS1000/2000 User Instructions

6.4 Commands and Response

Command: W<CR> (57h 0dh), request current reading

Command: S<CR> (53h 0dh), request current status

Command: Z<CR> (5ah 0dh)

If ZERO function cannot be activated, it will return to current scale status.

Command: T<CR> (54h 0dh)

If TARE function cannot be activated, it will return to current scale status.

Response

<LF>^^^^^^^^U

1

U

2

<CR><LF> H

1

H

2

H

3

<CR><ETX>---over capacity

<LF>_ _ _ _ _ _ _ _ U

1

U

2

<CR><LF> H

1

H

2

H

3

<CR><ETX>---under capacity

<LF> - - - - - - - - U

1

U

2

<CR><LF> H

1

H

2

H

3

<CR><ETX>---zero-point error

Note: If the weigh unit is lb:oz, U

1

U

2

oz in above responses

<LF><P>W

1

W

2

W

3

W

4

W

5

W

6

<DP>W

7

U

1

U

2

<CR><LF> H

1

H

2

H

3

<CR><ETX>---scale is stable and the

current weigh unit is kg or lb. With or without decimal point and the position is as per the P9 setting.

<LF><P>W

1

W

2

W

3

lb<SP>W

4

W

5

lb<SP>W

6

W

7

oz<CR> H

1

H

2

H

3

<CR><ETX>

<LF><P>W

1

W

2

W

3

lb<SP>W

4

lb<SP>W

5

W

6

<DP>W

7

oz<CR> H

1

H

2

H

3

<CR><ETX>

Response

<LF> H

1

H

2

H

3

<CR><ETX>

Response

Zero function is activated (simulate ZERO key) and it returns to current scale status.
<LF> H

1

H

2

H

3

<CR><ETX>

Response

TARE function is activated (simulate TARE key), and then returns scale status.
<LF> H

1

H

2

H

3

<CR><ETX>