Mount the unit in the upright position close to the ceiling inside the

cellar. As warm air rises to the top of the cellar, the cooling unit pulls the

warm air through the evaporator coil and removes the heat from the

warm air. Once cooled, the cold air is discharged from the front of the

cooling unit and circulates through the cellar.

Slide the unit through from the outside of the cellar.

CAUTION

: Two

people are required to move the cooling unit, which is very heavy.

Do not place the cooling unit on unprotected bottle racks.

Tilt the cooling unit slightly backwards. The rear of the cooling unit

should be slightly lower than the front of the cooling unit to facilitate the

flow of excess condensate to the drain line.

Use our adjustable mounting brackets to support and anchor the cooling

unit to the framing in the wall. Use the (16) #10x1-1/2” flat Phillips head

wood screws provided to anchor the screws into the studs and braces.

The mounting brackets can be used either inside or outside the cellar and

can be used in three different locations, as shown below.