Power Requirements

CellarPro cooling systems should be plugged into a dedicated non-GFI
outlet connected to a 15-amp circuit. The cooling unit uses approximately
11.5 (4200) and 9.2 (3200) amps during its “on” cycle.

A number of variables, including the minimum set point, the temperature
in the ambient environment, the insulation of the cellar, and the thermal
mass inside the cellar, will affect the cooling unit’s runtime. It is normal for
the cooling unit to run up to 75 percent of the time in order to maintain
proper conditions inside the cellar.

Select a power receptacle (Front or Rear) and plug the provided power
cord into that receptacle. Plug the other end of the power cord into a
dedicated 15 amp circuit. A surge-protected circuit is recommended.
Set the power selector switch to energize the appropriate receptacle
used (Front or Rear).

The power cord provided for the model 3200VSi and 4200VSi is approved
for indoor use only, while the power cord for model 3200VSx and 4200VSx
may be used both for indoor or outdoor applications.