25

V9.14

Remote Control / Display Instructions



Digital
Display

The temperature displayed on the control is red instead of blue.

Quick Chill
Button

Button

Icon

To activate the “Quick Chill” mode, press the “Up” button for three seconds

To deactivate “Quick Chill”, press the “Up” button for three seconds again
The “Quick Chill” indicator (Row 3) light will turn on when the cooling unit is
in “Quick Chill” mode,
In the “Quick Chill” mode, the cooling unit will run continuously for 6 hours
(or until the unit reaches set point.). This mode is useful after loading
“warm” bottles in the cabinet.

Auto Defrost
Mode

The cooling unit has a factory default defrost cycle that initiates every 16
hours for 20 minutes. When the cooling unit is in auto-defrost mode, the
“Defrost” Indicator light (Top row) will turn on, and the evaporator fan will
run.

Manual
Defrost

Hold the defrost button in for 3 seconds to initiate a manual defrost. The
“Defrost” Indicator light (Top row) will turn on for a 20 minute defrost cycle.

Light

The light button function is disabled, however pressing it will turn on/off the
light indicator on the display (2nd row).

Energy
Saver

The remote display is not configured with an Energy Saver mode. The set
point can be raised manually for periods where energy savings is desired.

Advertising