HUMIDITY: The factory preset for this setting is “3”.
If the humidity inside the cellar is too low, press the

“Set” button, then use the “Up” button until the desired

setting is reached. The recommended range for this

setting is 0-6.

TEMPERATURE DIFFERENTIAL: The factory preset for this

setting is “4”.

This setting determines the Temperature Differential

and therefore the temperature at which the cooling

unit will cycle on. The recommended range for this

setting is 4 or 5.
HIGH TEMPERATURE ALARM: The factory preset for this

setting is “70”.
This setting designates the High temperature inside

the cellar at which the alarm is triggered. We

recommend leaving this setting at the factory preset.

Advanced Operation

CellarPro cooling systems can be programmed with advanced settings to
achieve more control over conditions inside the cellar. Conditions like
humidity, the Temperature Differential, and alarm settings all can be
modified for custom applications. To access the advanced settings, do the
following:

Press the “Set” button and the “Down” button together at the same

time, and hold for three seconds. Then, use the “Up” or “Down” button to
scroll to the following screen:

LOW TEMPERATURE ALARM: The factory preset for this

setting is “45”.
This setting designates the Low temperature inside the

cellar at which the alarm is triggered. We recommend

leaving this setting at the factory preset.

ENERGY SAVINGS MODE DIFFERENTIAL: The factory preset

for this setting is “4”.
This

setting

increases

or

decreases

the

Temperature D i f f e r e n t i a l f o r t h e E n e r g y

S a v i n g s M o d e . T h e recommended range for this

setting is 2-4.