Fig. 5] step 5) weep baffle installation, Fig. 6, Step 6) end dam installation – EFCO 904 Series User Manual

Page 17: Head and sill can

Advertising
background image

The end dam must seal to the web of the jamb member (not shown).

[FIG. 5]

STEP 5) Weep Baffle Installation

Tool sealant over the inside edges of the dam to insure a water seal.

Install the dams in the ends of the head and sill flush with the end.

[FIG. 6]

1/2 HCW6

STEP 6) End Dam Installation

WEEP HOLE

See Fig. 6.

SEALANT

BAFFLE

DPS 7/2001

HN31 - 1" GLAZING POCKET [902 & 904]

HN30 - 1/4" GLAZING POCKET [901 & 903]

SEALANT

WEEP HOLE

BAFFLE

PAGE 15

HEAD AND SILL CAN

SECTION III C - FABRICATION

(CONT.)

APPLY A SMALL AMOUNT OF SILICONE TYPE

SEALANT TO THE BAFFLES THAT WILL

STRADDLE THE DRILLED WEEP HOLE, AND

LOCATE THEM OVER THE WEEP HOLES AS

SHOWN. DO NOT PLUG THE WEEP HOLES

WITH SEALANT. CUT HCW6 IN HALF TO

CREATE CORRECT SIZE BAFFLES.

SEE FIG. 17 ON PAGE 23.