CAPTURED VERTICALS

5/8" NOTCH AT

2 PC. JAMBS ONLY

1" NOTCH AT

8583

.542

DPS 7/2001

NOTCH

SECTION III G - FABRICATION

HORIZONTAL CUT LENGTH FORMULAS

CUT LENGTH = EXTERIOR D.L.O. {at BUTT GLAZED MULLION to

CUT LENGTH = EXTERIOR D.L.O. + 1 1/4" {at CAPTURED VERTICAL MULLION to

CUT LENGTH = EXTERIOR D.L.O. + 1 5/8" {at 2 pc. JAMB to

CUT LENGTH = EXTERIOR D.L.O. + 1" {at 2 pc. JAMB to BUTT GLAZED MULLION

NOTCH

5/8" x 7/32" NOTCH IS REQUIRED AT CAPTURED VERTICALS ONLY.

1" x 7/32" NOTCH IS REQUIRED AT 2 PC. JAMBS ONLY.

5/8" LONG

**

1" LONG

CAPTURED VERTICAL MULLION

PLEASE REFERENCE PAGE 35 FIG. 36.

[Fig. 14]

#10-24x

AT VERTICALS

9469 SIMILAR

8583 SHOWN

.344 (11/32") DRILL
BOTH ENDS

AT JAMB

1/2" F.H.

(S110)

CAPTURED VERTICAL MULLION

BUTT GLAZED MULLION

[Fig. 15]

INTERMEDIATE HORIZONTAL

PAGE 22

THE FOLLOWING PREPS APPLY TO 902 AND 901 ONLY.

SYSTEMS 903 AND 904 HAVE A ’SNAP FIT’ TO THE SHEAR

BLOCK AND DO NOT REQUIRE DRILL/SCREW ATTACHMENT

OR NOTCHING.