Door frame installation, Condensation" brochure, Fig. 56 – EFCO 904 Series User Manual

Page 49: Step 4) step 2) step 3) step 1)

Advertising
background image

and also in Fig. 57 through Fig. 60 on page 48.

Anchor the door frame and threshold as indicated below in Fig. 56 below

Set the assembled door frame in the opening, plumb and level.

(9950)

THRESHOLD

OF SEALANT

CONTINUOUS BEAD

See the parts description pages in SECTION II for the appropriate
door jamb and transom bar for the system being used.

jamb, continuing under the threshold to the opposite jamb and

connected from the side lite sill can/condition through the door

The concept is to have a continuous bead of sealant at the interior

sealant into the bead of sealant to be applied under the threshold.

to set the member into. Tie the side lite sealant or condition

Apply a bead of sealant around the interior portion of the jamb

SECTION VI A - DOOR FRAME INSTALLATION

Correctly locate the entrance frame in the opening.

NOTE: If an entrance frame is required, it must be installed first.

onto the opposite side lite sill can.

[FIG. 56]

floor and is cut longer

K-153/K-154 Threshold Clip & Screws

@ Concealed Rod Panic

K-124/K-125 Threshold Clip & Screws

than any other vertical

@ Offset Pivots & Butt Hinges

member.

SIDE LITE SILL CAN

The door jamb runs to the

NOTE:

STEP 4)

STEP 2)

STEP 3)

STEP 1)

DPS 7/2001

12" MAX.

THRESHOLD FASTENER

12" FROM JAMB & 12" O.C.
(3) PER SINGLE DOOR