8. Assembly, Disassembly

KISS 4U V2 – User's Guide (Version 1.01)

8.5. Installation in a 19" Industrial Cabinet

Expansion card installation should be performed before installing the KISS 4U V2 system into a
19" industrial cabinet.

Please consider the instructions described in the section 8.4Accessing Internal Components”.

Before closing the industrial cabinet, you must connect your peripherals to the corresponding system
ports.

For KISS 4U V2 versions and system configurations, please refer to the corresponding
“KISS 4U V2 Systems - Configuration Guides” on our website

www.kontron.com

.

More information and technical data can be found in the corresponding board manual (motherboard or
SBC, depending on the system configuration ordered).
You can download the manual from our web site at

www.kontron.com

by selecting the product.

In order to setting-up installing / removing the KISS 4U V2 platform into/from a 19" industrial cabinet,
please observe the instructions described in this manual.

4

Please consider the corresponding safety instruction included in chapter and the provided document
“General Safety Instruction for IT Equipment”.

The system has to be mounted and installed only by qualified personnel for this area familiar with the
associated dangers.

Ensure there is sufficient air circulation around the device when installing the KISS 4U V2 platform.

The openings for air intake and exhaust on the device must not be obstructed by objects.

Leave at least 5 cm (1.969 ") of free space in front and behind the KISS 4U V2 platform to prevent the
device from possibly overheating.

The KISS 4U V2 platform should be installed into a 19" industrial cabinet by use of slide rails or by use of
corresponding L-rack mounting brackets (not available).

For the installation of the KISS 4U V2 platform in a 19" industrial cabinet, you can order from Kontron
slide rails (PN: 1016-5807) and the “Rack Slide Rails Kit for KISS 1U and KISS 2U/4U”
(PN: 1051-7200).

The KISS 4U V2 platform should be installed into a 19" industrial cabinet with slide rails.

The 19" industrial cabinet must stand firmly in place. You can improve its stability by placing the
components into it from the bottom up. Heavy components should be placed down below.

If further stabilization is necessary, then bolt the 19" industrial cabinet to the floor or anchor it on the
wall.

The voltage feeds must not be overloaded.

Adjust the cabling and the external overcharge protection to correspond with the electrical data indicated
on the type label.

The type label is located on right side of the unit.