Fig. 39: filter mat holder without filter mat, Fig. 40: filter mat holder with filter mat, Fig. 41: filter mat – Kontron KISS 4U X9SCAF User Manual

Page 39: 4 and fig. 39, Fig. 38, pos. 3) into the marked direction (see, Fig. 41

Advertising
background image

10. Maintenance and Prevention

KISS 4U V2 – User's Guide (Version 1.01)

6. After cleaning and drying the filter pad, place it in the filter mad holder (see Fig. 40).

7. Reattach the filter mat holder to the front side of the fan slide-in module by inserting the positioning plates (Fig. 39,

pos. 6) into the positioning holes (Fig. 38, pos. 3).

8. Fix the filter mat holder by tightening the knurled screw (Fig. 39, pos. 5) to the bolt with tapped hole (Fig. 38, pos. 1)

at the fan slide-in module.

Defective components may only be replaced by Kontron original spare parts.

Air filter mat: part number: 1035-6957.

5

Fig. 38: Detail: without filter mat at the front side

Fig. 39: Filter mat holder without filter mat

Fig. 40: Filter mat holder with filter mat

Fig. 41: Filter mat

Legend for Fig. 38 and Fig. 39:

1 Fan slide-in module with bolt with tapped hole

2 Air intake openings at the front side of the fan slide-

in module

3 Positioning holes for the filter mat holder

4 Filter mat holder

5 Knurled screw of the filter mat holder

6 Positioning plates of the filter mat holder

1