12. Technical Data

KISS 4U V2 – User's Guide (Version 1.01)

12.2. Mechanical Specifications

Dimensions

KISS 4U V2

Height

4U (177 mm) (6.968 ")

Width

Front: 19” (482 mm); Chassis: 430 mm (16.9")

Depth

Chassis: 472.5 mm (18.6")

Weight (without Packaging)

Approx. 18 kg (39.6 lbs.)

Chassis

Chassis, black (RAL 7021)

Front access panel, blue (RAL 5017)

12.3. Environmental Specifications

Thermal Management

2x System fan, temperature controlled (fan slide-in module)
1x CPU fan
1x PSU fan

Operating Temperature

0 … +50 °C (+55 °C at 10% POH per month)

(32 .. 122 °F (131 °F at 10% POH per month)

Storage / Transit
Temperature

-20 … +70 °C
-4 … 158 °F

Relative Humidity
(Operating/Storage/Transit)

10-95 % @ 40° C, non condensing

Max. Operation Altitude

2,0000 m (6,560 ft)

Max. Storage / Transport
Altitude

10,000 m (32,810 ft)

Operating Shock

15 G, 11 ms, half sine

Storage / Transit Shock

30 G., 11 ms, half sine

Operating Vibration

10 – 500 Hz, 1.0 G

Storage / Transit Vibration

10 – 500 Hz, 2.0 G

Acoustic Noise

< 35 dB(A) at 1 m in front of the system
∼ 40 dB(A) for systems with Intel® Quad Core™ processor or redundant PSU

Protection Class

Front: IP20; optional IP52