Commands 21
Read Setpoint Hysteresis as Float
Command: 321, 0x141
Parameter: Setpoint number
Command 321 returns the hysteresis value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a
hysteresis value. Batch status is returned in place of the indicator status.
Read Setpoint Bandwidth as Float
Command: 322, 0x142
Parameter: Setpoint number
Command 322 returns the bandwidth value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a
bandwidth value. Batch status is returned in place of the indicator status.
Read Setpoint Preact as Float
Command: 323, 0x143
Parameter: Setpoint number
Command 323 returns the preact value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a preact
value. Batch status is returned in place of the indicator status.