22 ProfiNet Installation and Programming Manual
5.0
ProfiNet Interface Specifications
Power Requirements
Bus Adapter Card with ProfiNet Module, DC Power:
Supply voltage:
6 VDC
Typical current draw: 270 mA
Power consumption: 1.62 W
Indicators, Typical AC Load:
880
Power (TRMS): 3.51 W
Current (TRMS):33.7 mA
Communications Specifications
ProfiNet Network Communications:
Twisted-pair cabling up to 100Mbits/s
Update rate is dependent on the configured baud rate and the number of network nodes.
Maximum update rates are:
880:
up to 120 updates/sec
Environmental Specifications
Temperature:
–10° to +40° C (14° to 104° F)
Conformance
The ProfiNet Interface has been tested by ODVA’s independent test lab and found to
comply with the ODVA composite conformance test, revision 17.
Complies with Profinet IO conformance class B