0 profinet interface specifications, Profinet interface specifications – Rice Lake 880 Performance Series Panel Mount Indicator/Controller - ProfiNet Interface Option Installation and Programming Manual User Manual

Page 26

Advertising
background image

22 ProfiNet Installation and Programming Manual

5.0

ProfiNet Interface Specifications

Power Requirements

Bus Adapter Card with ProfiNet Module, DC Power:

Supply voltage:

6 VDC

Typical current draw: 270 mA
Power consumption: 1.62 W

Indicators, Typical AC Load:

880

Power (TRMS): 3.51 W
Current (TRMS):33.7 mA

Communications Specifications

ProfiNet Network Communications:

Twisted-pair cabling up to 100Mbits/s

Update rate is dependent on the configured baud rate and the number of network nodes.
Maximum update rates are:

880:

up to 120 updates/sec

Environmental Specifications

Temperature:

–10° to +40° C (14° to 104° F)

Conformance

The ProfiNet Interface has been tested by ODVA’s independent test lab and found to
comply with the ODVA composite conformance test, revision 17.
Complies with Profinet IO conformance class B

Advertising