Introduction

1

About This Manual

This manual provides information needed to install and use the Rice Lake Weighing
Systems ProfiNet Interface. ProfiNet allows the indicator to communicate with a
master controller on a ProfiNet network.

1

See the indicator installation manual for

additional installation information and detailed descriptions of indicator functions.
The ProfiNet is installed inside the indicator enclosure. Installation in NEMA 4X
stainless steel enclosures permits use in washdown environments.

WARNING

Some procedures described in this manual require work inside the
indicator enclosure. These procedures are to be performed by
qualified service personnel only.

Authorized distributors and their employees can view or download this
manual from the Rice Lake Weighing Systems distributor site at
www.ricelake.com.

1.0

Introduction

ProfiNet

returns weight and status information from an indicator to a master

controller and provides limited control of indicator functions to the
programmer. Indicator configuration and calibration cannot be performed
through the

ProfiNet Interface

.

The master controller sends commands to the indicator through

ProfiNet

by

writing the commands in the output command format. The

ProfiNet Interface

returns the weight and status data in the input command format. These actions
are referred to as polled I/O. See Section 3.0 for descriptions of the polled I/O
commands.