2 entering totals softkey menu – Rice Lake 920i FlexWeigh Systems - 103 User Manual

Page 20

Advertising
background image

16

System 103 Loss-in Weight Dispensing Controls

Slow Cycle Time

If a refill or dispense is not complete within the slow cycle time, the system will turn off all outputs and remain in a
paused state.

1. Enter the desired slow cycle time using the arrow keys and the numeric keypad.

2. Press

enter

on the 920i to save that value.

Entering a timer value of zero (0) disables the Slow Cycle Timer function.

Figure 4-7. Enter the Cycle Time

Exit

Press the

Exit

softkey to leave the presets menu parameters.

4.2

Entering Totals Softkey Menu

Note that the front panel E-stop button must be in the stopped position to enable the following
keypad entries.

Figure 4-8. Printing and Clearing Accumulators Menu

1. Press the

Totals

softkey.

2. The operator can print and reset the consecutive number, subtotal and totals by pressing the appropriate

softkey. Parameters that can be edited include:

• Consecutive Number

• Print Sub Total

• Print Total

Note

- - - - -

Target

Dribble

Preact

High Level

Consec. #

Subtotal

Total

100.0 Lb

75

0.0

500 Lb

2

0.0 Lb

0.0 Lb

Home


End

05/20/2011

10:27AM

SCALE #1

SCALE
#1

Gross
Lb

Low Level

150 Lb

Cancel

Enter Cycle Time (sec)
=> 12.0

Enter Cycle Time (sec)

Note

- - - - -

Target

Dribble

Preact

High Level

Consec. #

Subtotal

Total

100.0 Lb

75

0.0

500 Lb

2

0.0 Lb

3468 Lb

Presets

Setup
Menu

Totals

05/20/2011

10:21AM

SCALE #1

SCALE
#1

Gross
Lb

Low Level

150 Lb

Advertising