2 entering totals softkey menu – Rice Lake 920i FlexWeigh Systems - 103 User Manual
Page 20
16
System 103 Loss-in Weight Dispensing Controls
Slow Cycle Time
If a refill or dispense is not complete within the slow cycle time, the system will turn off all outputs and remain in a
paused state.
1. Enter the desired slow cycle time using the arrow keys and the numeric keypad.
2. Press
enter
on the 920i to save that value.
Entering a timer value of zero (0) disables the Slow Cycle Timer function.
Figure 4-7. Enter the Cycle Time
Exit
Press the
Exit
softkey to leave the presets menu parameters.
4.2
Entering Totals Softkey Menu
Note that the front panel E-stop button must be in the stopped position to enable the following
keypad entries.
Figure 4-8. Printing and Clearing Accumulators Menu
1. Press the
Totals
softkey.
2. The operator can print and reset the consecutive number, subtotal and totals by pressing the appropriate
softkey. Parameters that can be edited include:
• Consecutive Number
• Print Sub Total
• Print Total
Note
- - - - -
Target
Dribble
Preact
High Level
Consec. #
Subtotal
Total
100.0 Lb
75
0.0
500 Lb
2
0.0 Lb
0.0 Lb
Home
End
05/20/2011
10:27AM
SCALE #1
SCALE
#1
Gross
Lb
Low Level
150 Lb
Cancel
Enter Cycle Time (sec)
=> 12.0
Enter Cycle Time (sec)
Note
- - - - -
Target
Dribble
Preact
High Level
Consec. #
Subtotal
Total
100.0 Lb
75
0.0
500 Lb
2
0.0 Lb
3468 Lb
Presets
Setup
Menu
Totals
05/20/2011
10:21AM
SCALE #1
SCALE
#1
Gross
Lb
Low Level
150 Lb