3 dispensing material from a scale – Rice Lake 920i FlexWeigh Systems - 103 User Manual

Page 22

Advertising
background image

18

System 103 Loss-in Weight Dispensing Controls

Print Total

1. Press the

Totals

softkey (Figure 4-8) to access the

Print Total

softkey.

2. Press the

Print Total

softkey to access the following screen.

Figure 4-11. Clear Total Screen

3. Press the

Yes

softkey to clear the total and sub-total of the batch.

Press the

No

softkey to exit out of the screen.

4.3

Dispensing Material from a Scale

1. Press the

Start

button on the unit. The system verifies if:

• E-Stop is pulled out

• A valid target weight is entered

The system verifies the weight to make sure it’s above the target weight and above the low level weight. If
the weight is below the low level weight, it will refill the scale to the high level weight. When the weight
reaches the high level weight, the refill output will turn off.

2. Press the

START

button to start the dispensing material.

The system does the following during this process.

• Turns off the Dispense Complete and Refill Complete outputs

• Increments the consecutive number by one

• Tares the scale to zero (net mode)

The system begins dispensing either of three speeds while the 920i screen displays real time sequence
progress. The displayed net weight will continue showing more negative as weight is dispensed, until the
target weight presets are achieved.

- - - - -

Target

Dribble

Preact

High Level

Consec. #

Subtotal

Total

100.0 Lb

75

0.0

500 Lb

2

0.0 Lb

0.0 Lb

Yes


No

05/20/2011

10:31AM

SCALE #1

SCALE
#1

Gross
Lb

Low Level

150 Lb

Clear Total?

Advertising