Pausing/Resume/Reset a Dispense

19

Figure 4-12. Dispense Screen

The three dispensing speeds include:

• Single speed dispensing - The system turns on fast dispense until the target weight/preact weight is

satisfied.

• Parallel speed dispensing - Turns on the fast dispense and slow dispense until the dribble weight is

satisfied. The system then turns off the fast dispense and leaves the slow dispense on until the target
weight/preact weight is satisfied.

• Dual speed dispensing - Turns on the fast dispense until the dribble weight is satisfied. The system turns

on the slow dispense until the target weight/preact weight is satisfied.

The system does the following when the target/preact is reached.

• Turns off the output based on the dispensing mode

• Update the subtotal weight and number of dispenses

• Updates the total and number of dispenses

• Turns on the Dispense Complete output

The system delays for the Delay After Dispense time. After the delay, the weight display then switches to gross
weight and:

• If the gross weight is below low level weight the Refill output will automatically turn on until the gross

weight exceeds the high level weight.

• If the gross weight is above low level weight system, the system resets for the next cycle beginning with

Step #1.

4.4

Pausing/Resume/Reset a Dispense

1. Press the E-Stop button. System turns off all outputs and displays

System Paused

.

2. Press the

Resume

switch to resume where the current batch left off.

Press the Reset switch to return back to Step 1 to start over.

250

Target

Dribble

Preact

High Level

Consec. #

Subtotal

Total

100.0 Lb

75

0.0

500 Lb

2

120 Lb

3200 Lb

05/20/2011

10:28AM

SCALE #1

SCALE
#1

Gross
Lb

Low Level

150 Lb

Fast Dispense