Setpoint 1 in Example 3 is the under setpoint and sounds intermittently until it reaches the over setpoint (2).

Example 3

Setpoint 1 = 500 pieces

SPEC16 0100

Setpoint 2 = 400 pieces

Intermittent

No

Buzzer

Buzzer

0 |<-––––——————> |_______________

400

500

To program general setpoints:

1. Press MODE. The Weight display shows ProG.

2. While holding REZERO, press + key (release REZERO). The Quantity display shows SEt 1.

3. Enter target weight or count. Whether weight or count setpoints are used depends on initial specifica-

tion program of scale. The default is count setpoints. For more information, see default specs in
Section 6, Setting Configuration. Weights must be entered exactly as they appear in Weight display,
for example 10.000, not 10.

4. Press +. The Quantity display shows SEt 2.

5. Key in setpoint pre-alarm percentage.

6. Press +, then press MODE twice to return to normal operation.

Note:
To clear general setpoints, proceed as above but enter 0 for Set 1 and Set 2. Entering the setpoint mode clears
the unit weight setting. See Section 9.4 for more information about setpoint outputs.

4.6

Parts “In-Out” Operation

You can enter parts into the scale inventory and remove existing parts using the following procedures. See
Section 5.0, Data Storage, for information on programming code numbers. To enter parts:

1. Enter parts code number.

2. Press #.

Note:
If the code number has not been programmed into memory, the Quantity display shows “not F”. Press
CLEAR.

3. Place empty container equal to tare weight on platform.

4. Press # twice to set IN lamp on.

5. Place parts to be added to inventory on platform.

6. Press * to enter that quantity.

7. To return to normal operation, press MODE twice.

To remove parts:

1. Enter parts code number.

2. Press #.

3. Place empty container tare weight on platform.

4. Press # key to set the OUT lamp on.

5. Place parts to be taken from inventory on platform.

6. Press * to subtract that quantity from inventory.

7. To return to normal operation, press MODE twice.