How to enter and exit system setup – Rice Lake DWM-IV Weighmeter Standard Operators Manual User Manual

Page 19

Advertising
background image

How to Enter and Exit System Setup

Locate the small dip switch block in the lower right corner of the mother board. Turn on

S1, the display should then show FSE F1.

From the FSE Fn display you may scroll forwards and backwards using the [TARE] and

[ZERO] buttons. When the page you want is displayed, press [PRINT] to accept and view

the first step in that page.

Example: If the setup switch S1 is turned on, the display will show FSE F1. Press

[ZERO] button. The display will show FSE F6, press [PRINT], display will show F6.0 n.

You may now change the current setting for F6.0 by pressing [TARE], accept the setting

by pressing [PRINT], or backup to F5.9 by pressing [ZERO].

You may also go directly to the page you wish to change by pressing the page number

minus 1 on the keypad, after S1 is turned on. (Example: Operate S1. Display shows FSE

F1. Press 3. Display shows FSE F4.)

Upon completion of your changes you may exit and save without having to go all the way

to the end of the setup steps by pressing the [F1] button (on most units this will be an

unlabeled button under [RECALL/TARE], second down from the top, on the right hand

side). The display will go to FCd0. Press [PRINT] to save changes or press [TARE] to

change option to 1 or 2. Option 1 will discard all changes you have made (you can also

do this by turning off S1 at any time before the display shows FILEd. Option 2 (not

available on earlier software) is used to reset the factory defaults into the EEPROM

where all of the setup data is stored (U14 under the A/D board.).

Once you have selected which “FCd” option to use (usually “0” which is how it comes up

automatically) save your selection by pressing [PRINT] after about a second the display

should read FILEd, at this time you may turn off the setup switch S1 and return to the

weighing mode.

Function Select Enable Descriptions

:

F1 Contains settings that control the overall operation of the scale, such as averaging,

update rate, motion detection, zero tracking, etc.

F2 Tare functions, setpoint options & powerup options are set here.

F3 Serial port parameters, enabling of print fields, and custom formatting.

F4 Serial data output formats, modes.

F5 Enables individual right hand keyboard functions.

Page 17

Advertising