Rice Lake DWM-IV Weighmeter Standard Operators Manual User Manual

Page 20

Advertising
background image

F6 Calibration, capacity and increment size selection.

F7 Only available on custom systems.

Configuration Setting Descriptions

F1.0 Raw Counts Display

Enable Raw counts mode is used for diagnostic purposes and is also useful for

precalculating calibration settings. Once enabled, it will display the internal counts from

the A/D (analog/digital) converter which should fall between 250-100,000 counts on

standard software. If your display is showing top or bottom dashes it is already out of

range and raw counts will show the same indication. Check your wiring and millivolt

output from the load cell(s). This is the only configuration setting that does not have to be

written to permanent memory to take effect, just push [TARE] to set it to “E”, press

[PRINT] to accept the setting and turn off S1. The display will show all of the

annunciator arrows to show that it is in raw counts mode. To disable raw counts and

return to normal weighing, either repeat the above procedure setting to “d”, or simply

remove power. When you power the system back up raw counts mode will be disabled.

F1.1 Digital Averaging

Used to increase the stability of the weight readings. Higher settings will make the

display more stable in a noisy environment (wind, vibration, etc.), but will slow down the

display response. Lower settings will speed up the response but may cause excessive

motion and jitter in the display.

F1.2 Display Update Rate

This setting controls how often new readings are sent to the display. Higher settings will

make the display more responsive and give more of a scrolling number effect. Lower

settings will cause readings to appear to change all at once and may mask some

instabilities.

F1.3 Motion Detection

This controls how much the readings have to change to cause “motion” to be detected.

Motion detection is used to prevent printing, taring and zeroing of the scale when the

weight is unstable.

F1.4 Auto Zero Tracking Enable

F1.5 Auto Zero Tracking Width