Over Capacity: Displays OLOADat 102% of Full Scale Capacity.

Center Zero: Light indication when scale is within +/-0.25 digit of center of zero (0).

Load Cell Excitation: 15 VDC, powers up to twelve (12) 350 ohm load cells.

Input Sensitivity: 0.6 to 12 microvolts per digit.

Accuracy: 0.01% of full scale or +/- one digit, whichever is greater.

Data Output: Serial ASCII 20 mA current loop with selectable baud rates (150–19.2K),

selectable auto or manual print, continuous data out, or bi-directional communication.

Operating Temperature: -10 degrees C to +40 degrees C (+14°F to +104°F).

Humidity: Maximum: 95% RH non-condensing.

Power: 120 or 240 VAC, 50–60 Hz, 25 watts.

Fuse: 1/4A @ 120 VAC, 1/8A @ 240 VAC.

Dimensions: 12" (30.48 cm) H x 10" (25.4 cm) W x 5" (12.7 cm) D.

Weight: 16 lb (7.25 kg).