2 scale two, Scale two – Rice Lake OnTrak Truck Scale Data Management - Operation Manual User Manual

Page 15

Advertising
background image

Setting up OnTrak

11

Figure 3-8. Kiosk configuration settings.

11. Under

Scale One

, select

Kiosk Communications.

The right pane’s options will depend on the kiosk

communications method selected in Step 10.

12. If TCP/IP was selected for the kiosk communications method in Step 10, specify the IP address and TCP

port.

Figure 3-9. Kiosk Communications settings. TCP/IP (left) RS-232 (right).

13. If RS-232 was selected for the kiosk communications method in Step 10, use the drop-down menus to

specify the communications port, data bits, stop bits, baud rate, and parity.

3.2.2

Scale Two

1. From the left pane, expand the

Scale Two

selection.

2. Under

Scale Two

, select

Setup

.

3. From the

Scale Two Driver

pull-down menu, select the indicator connected to scale two.

If you are using one multi-channel indicator for both scales, select

Same as Scale One

.

4. From the

Source Channel

pull-down menu, select the desired channel you want to use.

Channel selection options will vary depending on which indicator is selected in Step 3. If you are using one
multi-channel indicator, ensure you choose a different channel for scale two than the channel used in scale
one.

5. From the

Communications Method

pull-down menu, select whether the indicator is connected via RS-232

or TCP/IP.

6. In the

Scale Label

text box, type a desired name for the scale.

7. Under

Scale Two

, select

Communications

.

8. In the right pane, specify the correct communications options. The options available will depend on

whether you selected RS-232 or TCP/IP in Step 5. See Figure 3-6 and Figure 3-7.