SET FACTORY DEFAULTS

Parameters in this menu listing with the
‘—’ symbol are the designated defaults.

SET FACTORY DEFAULTS

Overwrite the current settings with the
factory default settings or, if selected, will
restore the Factory Setting File.

;

Note: The reset will be automatic. If no Factory

Setting File is used, all menu settings will be
restored except CUSTOM ADJUSTMENTS, and
the media and ribbon sensor calibrations.

FORMAT ATTRIBUTES

Affects the manner in which overlapping
text and graphics are treated as the label is
printed. Consult the I & W Class
Programmer’s Manual for details.

TRANSPARENT

Intersecting text strings, images, and bar
codes will not be printed. (An odd number
of overlapping objects will print.)

—

XOR

Intersecting text strings, images, and bar
codes print on top of one another.

OPAQUE

Interacting text strings, images, and bar
codes are obliterated by those formatted
last. Each character cell is treated as
opaque.

IMAGING MODE

Instructs the printer whether to pre-image
the label format.

;

Note: This selection can affect the accuracy of

time-stamped labels and label throughput.

—

MULTIPLE LABEL

The printer images multiple labels as
memory permits, achieving the fastest
throughput; however, if time-stamping, the
time will reflect the moment the label is
imaged rather than when actually printed.

SINGLE LABEL

The printer images the next label only after
the previous label has been successfully
printed. Single processing provides time-
stamps that are more accurate, but it slows
label throughput time.