Rice Lake Datamax-ONeil I-Class Printer User Manual

Page 81

Advertising
background image

I-Class

71

5.0.2

Advanced Entry Calibration


Advanced Entry Calibration is the alternate method for special-case media
types. The procedure has two parts:

1) You must list the sensor readings for the label and TOF values using

different algorithms.

2) From your list the best algorithm is chosen, new readings taken and those

values entered.

Advanced Entry Calibration will override all previous calibration
settings; this method should be used only when Standard Calibration
has failed.


To perform an Advanced Entry Calibration:

Step

Operator Action

Displayed Message

Comment

1

(Media should be loaded
and the appropriate
Sensor Type selected.)

Turn ‘On’ the printer.


!

VODBMJCSBUFE

Wait until the

printer initializes
(about six
seconds).

2

Press the

Key.

Raise the printhead
assembly.


NFOV!NPEF

NFEJB!TFUUJOHT

!

You are entering
Menu Mode.

3

Press the Key
to enter the Media
Settings menu.


NFEJB!TFUUJOHT

NFEJB!UZQF

!

See Section 4.1.2

for menu layout.

4

Press the Key
and scroll to ‘Sensor
Calibration’.


NFEJB!TFUUJOHT

TFOTPS!DBMJCSBUJPO

!

Press the
Key to abort this
procedure.

5

Press the

Key.



TFOTPS!DBMJCSBUJPO

QFSGPSN!DBMJCSBUJPO

You are entering
the calibration
submenu.