72

I-Class

Advanced Entry Calibration (continued)

Step

Operator Action

Displayed Message

Comment

6

Press the

Key

to scroll to ‘Advanced
Entry’.


TFOTPS!DBMJCSBUJPO

BEWBODFE!FOUSZ

You are entering
Advanced Entry
Calibration.

7

Press the

Key.


BEWBODFE!FOUSZ

TFOTPS!MFWFMT

!

Press the
Key to abort this
procedure.

8

Press the

Key.


BEWBODFE!FOUSZ

TFOTPS!HBJO

!

You are beginning
the Advanced
Entry Calibration.

9

Press the

Key.

Place the label under the
Sensor Eye Mark and
lower the printhead
assembly.


HBJO!USBO!!!!!=zzz?

+11!!!!!!!!=1!.!42?

-OR-

HBJO!SFGM!!!!!=zzz?

+11!!!!!!!!)1!.!42*

If using preprinted
media, ensure the
label area under
the sensor is free
of preprinted text,
graphics or
borders.

10

Press the Key
to select the setting
(denoted by an ‘*’) and
then record the sensor
reading (the ‘yyy’ value)
in a table similar to the
one shown after Step 12,
as a Label Value.

Next, press the
Key to increment the
Gain Number.

Repeat this step for each
of the Gain Numbers
(00-32).


HBJO!USBO!!!!!=zzz?

+11!!!!!!!!=1!.!42?

-OR-

HBJO!SFGM!!!!!=zzz?

+11!!!!!!!!)1!.!42*

Where ‘yyy’ is a
numerical value
representing the
current sensor
reading: useful in
locating the best
sensor position.

; Note: Never
position the
sensor over a

perforation when
recording a
sensor reading.