Diagnostics

HEX DUMP MODE

Most commonly used for troubleshooting.
Prints data and instructions received from
the host rather than interpreting them as
label formats; see Section 6.2.

ENABLE

Prints raw ASCII data received from the
host rather than executing the commands.

—

DISABLE

Executes and prints label formats (normal
operating mode).

OPTIONS TESTING

Tests currently installed options

TEST PRESENT SENSOR

Performs a functional test of the Present
Sensor circuitry.

TEST CUTTER

Performs a functional test of the optional
cutter mechanism and circuitry.

PERFORM TEST
1 TIME

The cutter will cycle 1, 10 or 100 times
(selectable). The results of each attempt
will be displayed.

MONITOR GPIO INPUT

TEST GPIO OUTPUT

TEST SCANNER

Performs a functional test of the Scanner.

SCAN TEST

Enters “read once mode.” A bar code is
read and the decoded results are displayed.

ALIGNMENT TEST

Enters “constant read mode.” Bar codes
are read; decoded results are displayed;
and, a read-count is incremented.

PRINT TEST RATE (min)
—

000 (0-120)

The number of minutes to delay between
the printing of batches of labels in Quick
Test Mode.