3.7 Library

When an item is processed on a regular basis, the item’s data

(item or SKU numbers, Tare,

Check limits and Accumulated values) may be stored in memory for future use. This memory is

referred to as the scale’s Library.


Storing a record:

1. With the data established during operations, press the ID key, [Store] and [lib] are

displayed in the weight and piece weight windows respectively. The first vacant ID

number will blink in the count window.

2. Press ID key to save the data to the displayed ID number. Alternately, a different ID

number may be selected using the keypad and then pressing the ID key.

Note: Maximum 30 records, from 0 to 29.


Retrieving a record:

1. Enter the ID number using the keypad and press the ID key. [reCall] and [lib] are

displayed in the weight and piece weight windows respectively.

2. ID number is displayed in the weight window.

3. Press the ID or Yes key, [reCall] is displayed and the data is retrieved.


Editing a record:

1. Enter the ID number using the keypad and press the ID key. [reCall] and [lib] are

displayed in the weight and piece weight windows respectively.

2. Long press the ID key, [edit] and [lib] are momentarily displayed in the weight and

piece weight windows respectively.

3. Part number is displayed in the weight and piece weight windows. Default setting is

[000000] [000000]. Use the keypad to enter part number if required.

4. Press the Yes key to save the part number and advance to the preset Tare setting.

Use the keypad to enter a preset Tare value if required.

5. Press the Yes key to save the preset Tare value and advance to the APW setting.

Use the keypad to enter a new APW value if required.

6. Press the Yes key to save the APW and advance to the Limits setting.

Use the keypad to enter new under and over limits if required.

7. Press the Yes key to save the limits. [save] is displayed in the weight window. Press

the Yes key to save the data.


Clearing a record:

1. Enter the ID number using the keypad and press the ID key. [reCall] and [lib] are

displayed in the weight and piece weight windows respectively.

2. Press the C key, [delete] is displayed in the weight window. Press the Yes key to

delete the data.


Printing Library record:

A list of all library records stored in memory can be printed (see section 4.6)







Advertising